  1 digital timer h5cl easy-to-see and easy-to-operate din 48 x 48 mm digital timer with ip66/nema 4 protection water- and dust-protected for severe environ- ments. large, high-visibility led displays with a height of 12 mm. simple setting with increment and decrement keys. conforms to emc standards. six-language instruction manual provided. rc ordering information outputs supply voltage model w ithout finger safe t erminal cover w ith finger safe terminal cover contact output 100 to 240 v ac h5cl-a --- 12 to 24 vdc h5cl-ad h5cl-ad-500 t ransistor output (ph t l ) 100 to 240 v ac h5cl-as --- a s s o ou u (photocoupler) 12 to 24 vdc h5cl-ads --- model number legend: h5cl-a 2 3 1. fixed 2. d: dc supply v oltage 3. s: t ransistor output 1 accessories (order separately) name model hard cover Y92A-48 soft cover Y92A-48f1 t rack mounting/front connecting socket (for ac dl l) --- p2cf-11 ac ou g/ o co ec g soc e ( o c models only) finger safe type p2cf-11-e back connecting socket (for ac models only) --- p3ga-11 ac co ec g soc e ( o c ode s o y) finger safe type p3ga-1 1 with Y92A-48g (see note 1) finger safe t erminal cover for dc models Y92A-48t flush mounting adapter (see note 2) y92f-30 note: 1. Y92A-48g is a finger safe terminal cover which is attached to the p3ga-1 1 socket. 2. supplied with each unit.
h5cl h5cl 2 specifications item h5cl-a (ac models) h5cl-ad (dc models) classification digital timer mounting din track, surface, and flush mounting (common) flush mounting external connections socket screw terminals enclosure ratings panel surface: iec ip66 and nema t ype 4 (indoors) when y92s-29 rubber packing is used. digits 4 digits (zero suppress method) max. time settings 9.999 s (0.001-s unit), 99.99 s (0.01-s unit), 999.9 s (0.1-s unit), 9999 s (1-s unit), 99 min 59 s (1-s unit), 999.9 min (0.1-min unit), 99 h 59 min (1-min unit), 999.9 h (0.1-h unit) display modes up (increment) and down (decrement) (selectable) input signals start, gate, reset, and key protection input method no-voltage input: via npn transistor or switching of contact operating modes a (signal on-delay), f (accumulative operation) (selectable) reset system power reset (a (signal on-delay) mode only), external, manual resets sensor waiting time 216 ms typ., 250 ms max. (control output is turned off and no input is accepted during sensor waiting time.) external power supply 50 ma at 12 vdc ( 10%) --- display 7-segment leds (12 mm high, red leds for the present value, and 8 mm high, green leds for the set value) memory backup eep-rom (overwritten 200,000 times min.), which can store data for 20 years min. mounting method din track mounting, surface mounting, and flush mounting flush mounting approved standards ul 508, csa c22.2 no.14 conforms to en61010-1 ratings item h5cl-a (ac models) h5cl-ad (dc models) rated supply voltage 100 to 240 v ac, 50/60 hz 12 to 24 vdc (permissible ripple: 20% (p-p) max.) operating voltage range 85 to 264 v ac, 50/60 hz 10.8 to 26.4 vdc power consumption approx. 10 v a approx. 3 w start, reset, gate inputs min. pulse width: 1 ms/20 ms (selectable, same for all three inputs) key protection input response time: 1 s max. power reset min. power opening time: 0.5 s (excluding f (accumulative operation) mode) control output contact output: spdt , 3 a at 250 v ac, resistive load (cos f =1) min. applicable load: 10 ma at 5/24 vdc (p level, for reference value) t ransistor output: npn open collector , 100 ma max. at 30 vdc max., residual voltage 1.5 vdc max.
h5cl h5cl 3 characteristics item h5cl-a (ac models) h5cl-ad (dc models) deviation of operating time and setting error (including temperature and voltage influences) power start: 0.01% 0.05 s max. (see note 1) signal start: 0.005% 0.03 s max. (see note 1) signal start, at transistor output model: 0.005% 3 ms max. (see note 1 and 2) if the set value is within the sensor waiting time (250 ms max.) in the case of power start, the control output of the h5cl will not be turned on until the sensor waiting time passes. insulation resistance 100 m w min. (at 500 vdc) (between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts) dielectric strength 2,000 v ac, 50/60 hz for 1 min (between current-carrying terminal and exposed non-current-carrying metal parts) 1,000 v ac, 50/60 hz for 1 min (between non-continuous contacts) 1,000 v ac, 50/60 hz for 1 min (between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts) impulse withstand voltage 3.0 kv (between power terminals) 4.5 kv (between current-carrying terminal and exposed non-current-carrying metal parts) 1.0 kv (between power terminals) 1.5 kv (between current-carrying terminal and exposed non-current-carrying metal parts) noise immunity 1.5 kv (between power terminals) 600 v (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 m s, 1-ns rise) 480 kv (between power terminals) 600 v (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 m s, 1-ns rise) static immunity destruction: 15 kv malfunction: 8 kv v ibration resistance destruction: 10 to 55 hz, 0.75-mm single amplitude each in three directions malfunction: 10 to 55 hz, 0.5-mm single amplitude each in three directions shock resistance destruction: 294 m/s 2 (30g) each in three directions malfunction: 98 m/s 2 (10g) each in three directions ambient temperature operating: 10 to 55 c (10 to 50 c if timers are mounted side by side) (with no icing) storage: 25 to 65 c (with no icing) ambient humidity operating: 35% to 85% life expectancy mechanical: 10,000,000 operations min. electrical: 100,000 operations min. (3 a at 250 v ac, resistive load) emc (emi): en50081-2 emission enclosure: en55011 group 1 class a emission ac mains: en55011 group 1 class a (ems): en50082-2 immunity esd: en61000-4-2: 4 kv contact discharge (level 2) 8 kv air discharge (level 3) immunity rf-interference: env50140: 10 v/m (80 mhz to 1 ghz) (level 3) immunity conducted disturbance: env50141: 10 v (0.15 to 80 mhz) (level 3) immunity burst: en61000-4-4: 2 kv power-line (level 3) 2 kv i/o signal-line (level 4) case color light gray (munsell 5y7/1) weight approx. 130 g approx. 1 10 g note: 1. the values are based on the set value. 2. the value is applied for a minimum pulse width of 1 ms.
h5cl h5cl 4 nomenclature indicator 1. present v alue red leds with a character height of 12 mm note: the decimal point will flash on the present value dur - ing the timing operation in the following ranges: 0.1 to 999.9 min, 0 h 01 min to 99 h 59 min, and 0.1 to 999.9 h. 2. preset v alue green leds with a character height of 8 mm 3. reset indicator (orange) 4. key protection indicator (orange) 5. t ime unit display (orange) 6. control output indicator (orange) operation key 7. reset (rst) key the rst key initializes the present value and control output. 8. increment keys (1 to 4) up keys 1 to 4 increment the preset value. 9. decrement keys (1 to 4) down keys 1 to 4 decrement the preset value. 1 2 5 8 4 6 3 7 9 stick the enclosed label here. operation dip switch setting pin no. item off on 1, 2, 3 t ime ranges see table below . 4 display modes up (increment) down (decrement) 5 min. pulse width of inputs 20 ms 1 ms 6 operating modes a (signal on-delay) f (accumulative operation) note: set the dip switch before installation and operation of the unit. dip switch setting changes are not ef fective while the power is on. time ranges 1 2 3 time range on on on 0.001 to 9.999 s off off off 0.01 to 99.99 s on off off 0.1 to 999.9 s off on off 1 to 9999 s on on off 0 min 01 s to 99 min 59 s off off on 0.1 to 999.9 min on off on 0 h 01 min to 99 h 59 min off on on 0.1 to 999.9 h note: switches 1 to 6 are all set to off before shipping. (the same switch settings apply to ac and dc models) timer control with power start when using the h5cl with power start, short-circuit the start input and input 0-v terminals.
h5cl h5cl 5 operating modes a mode signal on-delay f mode accumulative operation power start gate reset control output set value 0 0 set value display mode power start gate reset control output set value 0 0 set value display mode up down up down dimensions note: all units are in millimeters unless otherwise indicated. h5cl-a din t rack/surface/flush mounting h5cl-ad flush mounting 48 48 48 48 64 72.5 14.4 6 6 44.8 x 44.8 (70) 44.8 x 44.8
h5cl h5cl 6 h5cl-a with flush mounting adapter h5cl-ad w ith flush mounting adapter panel cutouts panel cutouts are as shown below . (according to din43700). +1 0 a = (48n2.5) note: 1. the mounting panel thickness should be 1 to 4 mm. 2. it is possible to mount timers side by side, but only in one direction. 3. when the t imers are mounted closely side by side, the t imers will not be water-resistive. 58 (51) 48 98.7 7.5 (51) 48 58 7.5 y92s-29 rubber packing (provided) panel y92f-30 flush mounting adapter (provided) p3ga-11 back connecting socket (sold separately) y92s-29 rubber packing (provided) panel y92f-30 flush mounting adapter (provided) 62.5 60 min. 60 min. a n side by side mounting 45 +0.6 0 45 +0.6 0 44.8 x 44.8 h5cl-ad -500 the cover conforms to finger protection standard against electric shock. (vde 0106/p100) din track mounting 120 h5cl-a p2cf-11 64.5 47.5 7.5 58 48
h5cl h5cl 7 accessories (order separately) track mounting/ front connecting socket p2cf-11 terminal arrangement/ internal connections (t op v iew) surface mounting holes two, 4.5 dia. mounting holes 40 0.2 two, 4.5 dia. holes eleven, m3.5 x 7.5 sems 70 max. 50 max. 31.2 max. 7.8 3 4.5 35.4 4 p2cf-11-e (finger safe terminal type) conforming to vde0106/p100 two, 4.5 dia. holes eleven, m3.5 x 7.5 sems 7.8 70 max. 4 40 0.2 50 max. 35.4 31.2 max. 30 5 4.5 3 1.2 back connecting socket p3ga-11 terminal arrangement/ internal connections (bottom view) 45 45 27 dia. 25.6 4.5 16.3 6.2
h5cl h5cl 8 finger safe terminal cover conforming to vde0106/p100 Y92A-48g (attachment for p3ga-1 1 socket) Y92A-48t (attachment for h5cl dc models) hard cover Y92A-48 soft cover Y92A-48f1 twelve, 6.4 dia. holes 34 47.7 x 47.7 48 x 48 47.4 16.5 24.6 27.6 installation terminal arrangement ac models dc models note: 1 and 6 are connected to each other internally . 810 9 7 5 4 3 2 5 4 3 gate key protection 0 v reset start 12 to 24 vdc contact output transistor output 6 7 8 9 10 5 4 3 2 reset start gate key protection external power supply 12 vdc (50 ma max.) 11 1 8 9 11 transistor output contact output 100 to 240 vac input common (0 v) 6 1 + load (sensor) () (+) note: power supply circuit is insulated from the internal circuit (or i/o).
h5cl h5cl 9 input circuits start, reset, and gate input h5cl-a (ac models) key protection input in v in 3.5v (16v max.) 1 k w internal circuit v in : supply voltage h5cl-ad (dc models) in +12 v 1 k w internal circuit in internal circuit +5 v 4.7 k w note: no key input is effective while key protection input is on. input connections open collector output voltage output 12 vdc 1 7 6 5 3 7 9 8 6 pc or sensor 0 v output 12 vdc pc or sensor 0 v output ac models dc models 1 7 6 5 3 7 9 8 6 ac models dc models gate input start input reset input 12 vdc output gate input start input reset input 12 vdc output 0 v 0 v contact input 7 6 5 3 7 9 8 6 ac models dc models gate input start input reset input start, reset, and gate input specification on impedance: 500 w max. (the leakage current is 5 to 20 ma when the impedance is 0 w .) on residual voltage: 2 v max. off impedance: 100 k w min. maximum applicable voltage: 30 vdc max. two-wire sensor 7 6 5 3 7 9 8 6 sensor 0 v ac models dc models gate input start input reset input 0 v applicable t wo-wire sensor leakage current: 1.5 ma max. switching capacity: 5 ma min. residual voltage: 3 v max. operating voltage: 10 vdc note: when connecting a two-wire sensor to a dc models, sup - ply 24 vdc (21.6 to 26.4 vdc) to the timer . key protection input 4 3 10 6 ac models dc models open collector or contact 0 v key protection input key protection input on impedance: 1 k w max. (the leakage current is approx. 1 ma when the impedance is 0 w .) on residual voltage: 0.5 v max. off impedance: 100 k w min. maximum applicable voltage: 30 vdc max. note: the used contact should switch 1 ma at 5 v .
h5cl h5cl 10 precautions power supplies when turning the power on and off , input signal reception is pos - sible, unstable, or impossible as shown in the diagram below . power supply input impossible unstable possible impossible unstable 160 ms 0 to 90ms dc: 5 ms ac: 10 ms 0 to 500 ms on off apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately . turn the power on and off with relay with a rated capacity of 10 a minimum to prevent contact deterioration due to inrush current caused by turning the power on and off . timer control with power start the timer cannot take measurements until 160 to 250 ms have elapsed after the power is turned on (refer to the above chart). the control output will be delayed for any set value less than 250 ms. when the h5cl is used with power start in f mode (i.e., accumula - tive operation with output on hold), there will be a timer error (approximately 100 ms each time the h5cl is turned on) due to the characteristics of the internal circuitry . use the h5cl with signal start if timer accuracy is required. transistor output the transistor output of the h5cl is insulated from the internal cir - cuitry by a photocoupler, so the transistor output can be used as both npn and pnp output. the diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the h5cl. load timer power for load inductive load timer power for load self-diagnostic function the following displays will appear if an error occurs. display error output status correction set value after correction e1 cpu off press rst key or turn power of f and then on no change e2 memory (see note) 0 note: this includes times when the life of the eeprom has ex- pired. operating environment when using the t imer in an area with excess electronic noise, sepa - rate the t imer , wiring, and the equipment which generates the input signals as far as possible from the noise sources. it is also recom - mended to shield the input signal wiring to prevent electronic inter - ference. organic solvents (such as paint thinner), as well as very acidic or basic solutions can damage the outer casing of the t imer. preset v alue change when changing the preset value during a timing operation, output will turn on if the preset value is changed as follows, since the con - stant read-in system is in use: display mode up: present value preset value display mode down: elapse time preset value (present value = 0) note: when in down mode, the changed amount of preset value is added to or subtracted from the present value. reset with a preset value of 0 the output will go on when the start signal is input. the output will be off while the reset key is pressed or the reset input is on. power failure backup all data is stored in the eeprom when there is power failure. the eeprom can be overwritten more than 200,000 times. operating mode overwriting timing a mode when the h5cl is turned of f after changing the set value. f mode when the h5cl is turned of f after changing the set value, turning the start input, or the reset input on. flush mounting the h5cl ' s panel surface is water-resistive (conforming to nema 4 (indoors) and ip66). in order to prevent the internal circuit from wa - ter penetration through the space between the timer and operating panel, attach a rubber packing (provided with the h5cl) between the timer and operating panel and secure the rubber packing with the y92f-30 flush-mounting adapter . it is recommended that the space between the screw head and the adapter should be 0.5 to 1 mm. 0.5 to 1 mm other in case of performing a dielectric strength test, etc., on the h5cl mounted to a control panel, disconnect the h5cl from the connect - ing circuit, or short-circuit all the terminals of the h5cl. otherwise the h5cl may be damaged. terminal 1 (power supply terminal) and terminal 6 (input common: 0 v for input) of dc model h5cl are internally connected to each other. dip switch selection dip switch setting while the h5cl is turned on will not be valid until the h5cl is turned of f and on.
h5cl h5cl 11
h5cl h5cl 12 all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. t o convert grams into ounces, multiply by 0.03527. cat. no. l085-e1-3 in the interest of product improvement, specifications are subject to change without notice. printed in japan 1099-0.1m (0696) omron corporation industrial automation company measuring and supervisory controls division 28th fl., crystal t ower bldg., 1-2-27, shiromi, chuo-ku, osaka 540-6028 japan t el: (81)6-6949-6035 fax: (81)6-6949-6069


▲Up To Search▲   

 
Price & Availability of Y92A-48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X